Low-current (ELV) systems in buildings: a practical guide

Sard Solution engineering team · · 6 min read

Low-current or extra-low-voltage (ELV) systems are the building systems that carry signals and data rather than power: fire alarm, CCTV, access control, data networks, telephone, public address, intercom and building controls. They should be designed together with the power system, because they share routes, rooms and power supplies.

Common ELV systems and what they do

SystemPurpose
Fire alarmDetects smoke and heat and alerts occupants and responders
CCTVVideo surveillance, recording and review
Access controlControls who can open which doors, and when
Intrusion alarmDetects unauthorised entry
Structured cabling and dataThe network backbone for IT and IP-based systems
Public address and voice alarmAnnouncements, background music and evacuation messages
Intercom and nurse callCommunication between rooms, entrances and staff
MATV / IPTVTV distribution to rooms and screens
BMS and lighting controlAutomation of building services

Which ELV systems are mandatory?

Fire detection and alarm is required by the fire code for almost every occupied building, and in Saudi Arabia it is designed to the Saudi Building Code and approved through the Civil Defense. Other systems depend on the building type and its operator: hospitals need nurse call, hotels need guest room systems, and Saudi Arabia also regulates the use of security cameras for many types of facility. Confirm the requirements for your building early, before the design is fixed.

Why design ELV with the power system

  • Cable trays and conduits are shared or run in parallel and must be separated correctly.
  • ELV needs dedicated rooms: main equipment room, floor telecom rooms, fire alarm panel and control room.
  • Most ELV equipment needs clean, backed-up power from UPS or dedicated circuits.
  • Late ELV changes are the most common source of rework in fit-out.

IP convergence

Many ELV systems now run over IP: CCTV cameras, access controllers, intercoms, IPTV and BMS. Running them on one well-designed structured-cabling network, separated with VLANs, reduces cabling and makes expansion easier. Life-safety systems such as fire alarm usually stay on their own dedicated wiring as required by code.

ELV design checklist

  1. List every ELV system the building needs and the authority approvals each requires.
  2. Agree the room locations and sizes with the architect.
  3. Plan containment routes with power, keeping required separation.
  4. Define power and UPS requirements for each system.
  5. Decide which systems share the IP network and which stay separate.
  6. Define the integrations: fire alarm to access control, lifts and HVAC; CCTV to access control.

Frequently asked questions

What does ELV mean?

Extra-low voltage. In building projects it is used for low-current systems that carry signals and data, such as fire alarm, CCTV, access control and data networks.

Is ELV part of the electrical design?

Usually yes. ELV is normally designed by the electrical engineer alongside power and lighting, often with specialist input for security and IT.

Who approves fire alarm design in Saudi Arabia?

Fire alarm and life-safety systems are reviewed and approved through the Civil Defense, against the Saudi Building Code.